1 #include <iostream> |
|
2 #include <iomanip> |
|
3 |
|
4 /** |
|
5 * Translates text from standard input to a hex-formatted System Exclusive (SysEx) message for Roland MT-32, |
|
6 * which instructs the unit to show given text on the display. |
|
7 * |
|
8 * Roland MT-32 is capable to display 20 characters. |
|
9 * Longer messages are silently truncated by the MT-32 unit (this software does not check the length). |
|
10 * |
|
11 * The SysEx message contains a checksum. |
|
12 * If the checksum is wrong, the MT-32 unit shows the "Exc. Checksum error" message for few seconds |
|
13 * and then returns back to the default screen. |
|
14 * |
|
15 * Usage: |
|
16 * amidi --port="hw:2,0,0" --send-hex="$(echo -n ' Run GNU/Linux ' | ./mt-32-display )" |
|
17 * |
|
18 * @param argc |
|
19 * @param argv |
|
20 * @return |
|
21 */ |
|
22 int main(int argc, char**argv) { |
|
23 std::cout << "f0 41 10 16 12 20 00 00 "; |
|
24 std::cout << std::hex << std::setfill('0'); |
|
25 |
|
26 int sum = 0; |
|
27 |
|
28 // 20 00 00 = display message |
|
29 sum += 0x20; |
|
30 sum += 0x00; |
|
31 sum += 0x00; |
|
32 |
|
33 for (char ch; std::cin.read(&ch, 1).good();) { |
|
34 std::cout << std::setw(2) << ((int) ch) << " "; |
|
35 sum += ch; |
|
36 } |
|
37 |
|
38 sum %= 128; |
|
39 sum = 128 - sum; |
|
40 std::cout << std::setw(2) << sum; |
|
41 std::cout << " f7"; |
|
42 |
|
43 std::cout << std::endl; |
|
44 return 0; |
|
45 } |